Keep the refrigerator, lights and other essentials running when utility power goes out. SageCare Electric installs 30-amp and 50-amp generator inlets with an interlock or transfer switch selected for your home’s electrical system.
What would you need to keep using through a day without power? Tell us that, along with the generator you own or are considering, and we can work out the connection your home needs.
Free estimates with no dispatch charge. Calls answered 24/7, with an AI customer service assistant after regular business hours. Installation and on-site service are scheduled by appointment.
How the connection works
An inlet gives your generator cord a designated connection to the house. The interlock prevents the utility main breaker and generator supply breaker from being on together. With suitable equipment installed, you can use selected household circuits while staying within the generator’s limits. [1]
The inlet alone does not provide that protection. The breaker, wiring, transfer equipment and generator must work together. We check the panel’s exact model, its breaker arrangement, and the generator’s voltage, output and neutral configuration before choosing the equipment.
A standard interlock is operated manually. You start the generator and follow the procedure for your installed system, including keeping large loads off when they exceed available power. Automatic transfer requires a compatible generator and control arrangement; a remote-start key fob does not do the same job.
If you already own a generator, have its model number and intended fuel ready. A photo of the closed panel can help start the discussion. We confirm the installation requirements at the house.
Installation scope and price
Distance from the panel, the wire route, the connection rating and the approved transfer equipment all affect the price. An inlet beside a compatible panel is a different job from installing an automatic transfer switch or changing the electrical service.
Our written proposal identifies the inlet, wiring, breaker, interlock or transfer switch, any panel changes, and who handles permitting and inspection. Greenville County requires permits for electrical work; the authority responsible for your address may instead be a municipality. We confirm that when preparing the scope. [2]
We also identify whether the generator, cord, gas piping and any A/C soft start are included or separate. Drywall repair and painting are excluded unless listed. Workmanship and supplied-material guarantee terms appear in the written scope; customer-supplied equipment follows the manufacturer’s terms.
Before we finish, we test the installation and walk you through the transfer procedure and circuit choices. Booking before storm season gives you time for equipment selection, permits and that walkthrough. A generator still sitting in its box is not a finished backup system.
Some homes need panel upgrades or a service upgrade first. We explain any additional work before you approve the installation.
Recent inlet and interlock installations
These SageCare installations show several panel arrangements. The correct kit depends on the panel, not simply its brand or appearance.
30-amp or 50-amp?
A 30-amp connection can suit refrigeration, lighting, communications and other selected essentials. A 50-amp connection allows more capacity for a larger compatible generator. Neither tells us, by itself, whether the house can run its air conditioner or well pump.
Swipe the table sideways to see every column.
| Connection rating | 30 amp | 50 amp |
|---|---|---|
| Total at 240 V | 7,200 W 30 A × 240 V at power factor 1 | 12,000 W 50 A × 240 V at power factor 1 |
| Each 120 V leg | Up to 30 A, equivalent to 3,600 W at power factor 1 | Up to 50 A, equivalent to 6,000 W at power factor 1 |
| Typical priorities | Refrigerator/freezer, lights, internet and selected receptacles. A blower or pump may fit after review. | Additional essentials, with possible room for one compatible HVAC system after running and starting checks. |
| Still limited by | Generator output on the selected fuel, motor starts, cord and breaker ratings, and load balance. | The same factors, plus careful control of large appliances and heat strips. |
Those figures are nominal connection ceilings. They are not a promise of usable generator output. The lowest-rated part of the system, actual generator output, power factor and installation requirements can impose a lower limit. [3]
For example, an 8,500-watt generator cannot supply 12,000 watts because it has a 50-amp receptacle. Likewise, a larger generator connected through a 30-amp inlet is still constrained by that connection.
The people behind your installation
Christina keeps the office and scheduling moving. Ian leads the electrical work, with our field team handling installations across Greenville and the surrounding Upstate.
We serve Greenville, Piedmont, Powdersville, Easley, Simpsonville, Mauldin, Greer and Taylors, along with nearby communities. Our office address is 411 University Ridge, Suite B6, Greenville, SC 29601. Get to know SageCare Electric.
What can your generator run?
House size is a poor shortcut for generator sizing. A smaller all-electric home can need more backup power than a larger house with gas heat and gas cooking. Start with the actual appliances you intend to use together.
Running watts describe sustained output under the manufacturer’s rated conditions. Starting or peak watts describe brief output available when equipment such as a motor starts. A machine advertised at 13,000 peak watts is not necessarily capable of supplying 13,000 watts continuously. [3]
Motors do not start only when you first connect the generator. Refrigerators, pumps and compressors cycle during an outage, including after you have switched on other appliances. Account for those starts as well as the combined running load. [15]
Swipe the table sideways to see every column.
| Appliance | Example running demand | Other considerations |
|---|---|---|
| Efficient refrigerator or freezer | 132–192 W in Honda’s Energy Star example | About 1,200 W total at startup in the same example. Older or different units can vary. |
| Gas or oil furnace blower | 300–875 W in Honda’s examples | Motor size and controls affect starting demand. A gas furnace still needs electricity. |
| Sump pump | 800 W at ⅓ hp; 1,050 W at ½ hp | Corresponding total starting examples: 1,300 W and 2,150 W. |
| Ten 10-watt LED lamps | 100 W, calculated | Count the actual lights and other devices sharing the circuit. |
| Conventional electric water heater | 4,500 W in Honda’s example | Use the actual element rating. Electric tankless models can need much more. |
| Central A/C, heat pump or well pump | Use the equipment’s measured/nameplate demand | Voltage, motor startup, controls and heat strips matter. |
These are examples, not ratings for your appliances. The starting figures above are the appliance’s total starting demand, not extra watts to add to its own running figure. [4]
Portable Generator Running Wattage Calculator
Check what you want to use at the same time during an outage. We’ll add the estimated watts, allow room for the load and compare a 30-amp or 50-amp inlet with generator models.
Four examples selected: 550 W.
Your backup-power estimate
The selected refrigerator, freezer, lights and internet examples total 550 running watts.
These are example loads. SageCare can check your actual equipment and connection before you choose a generator.
About these estimates
We add the selected running watts and multiply by 1.25 for a planning allowance. This is not a universal electrical-code rule. The startup screen adds the largest single extra starting demand to the running total; overlapping motor starts can need more.
At nominal 120/240 V, 30 amps is 7,200 VA overall and 3,600 VA per 120 V leg; 50 amps is 12,000 VA overall and 6,000 VA per leg. Those equal watts at power factor 1. Actual output, load balance, starting performance and connection ratings still matter.
Values are examples, not measurements of your appliances. Refrigerators, including the medication-fridge choice, use a rounded efficient-appliance example. Internet uses a 50 W allowance. The microwave value is electrical input; the complete range uses a 12.1 kW nameplate example. Gas water-heater power covers electrical equipment, not gas heat; pumps and freeze protection may add demand.
CPAP and bilevel PAP use 110 W allowances based on ResMed AirSense 10 and AirCurve 10 examples: 53 W typical and 104 W AC peak. The oxygen example is Philips EverFlo’s 350 W average; its startup demand is unconfirmed. Other devices can differ.
Model ratings: pairs below are running/peak watts on each fuel. All five examples supply 120/240 V. Ratings checked November 27, 2026; verify the actual unit, especially older XP13000HXT revisions.
- Westinghouse WGen5300DFcv: gasoline 5,300/6,500 W; propane 4,800/5,800 W. 30 A outlet.
- DuroMax XP5500HX: gasoline 4,500/5,500 W; propane 4,275/5,225 W. 30 A outlet.
- Westinghouse WGen9500TFc: gasoline 9,500/12,500 W; propane 8,500/11,200 W; natural gas 7,500/9,500 W. 30 A and 50 A outlets.
- DuroMax XP13000HXT: gasoline 10,500/13,000 W; propane 10,000/12,500 W; natural gas 9,000/11,250 W. 30 A and 50 A outlets.
- Westinghouse WGen11500TFc: gasoline 11,500/14,500 W; propane 10,500/13,500 W; natural gas 9,500/12,000 W. 30 A and 50 A outlets.
Equipment and planning references: Honda household wattage guide · GE electric range specifications · Navien gas tankless electrical specifications · ResMed AirSense 10 power specifications · ResMed AirCurve 10 power specifications · Philips EverFlo power consumption · FDA medical-device outage planning · KOHLER standby startup explanation.
This calculator works on this page and does not submit or store your selections.
A circuit count is not a capacity calculation. A router and a few LED lights can share a circuit while using very little power. An electric water heater can use several thousand watts on one circuit. You also need to balance 120-volt loads between the generator’s two legs, keeping each within its rating.
Choosing fuel
On the portable models discussed here, dual fuel generally means gasoline or propane. Tri fuel adds natural gas. The generator uses one selected fuel at a time, following the manufacturer’s switching procedure.
Output changes with fuel. A generator chosen for its gasoline rating may have noticeably less capacity on propane or natural gas. Compare the running-watt figure for the fuel you expect to use. [5][6][7]
Think about how you will obtain fuel during the outage, how long you want the machine to run and who will handle refueling. Those details matter as much as the difference in rated output.
Gasoline
Often gives the highest published output on these models. It also brings fuel-storage, maintenance and refueling responsibilities. Follow the manual, and shut the engine down and let it cool before adding fuel.
Propane
A suitable cylinder or tank avoids gasoline refills, but fuel quantity is only part of the calculation. Temperature, tank size, fill level and regulator capacity affect delivery. A small grill cylinder is not automatically suitable for a large generator in cold weather.
Natural gas
Can reduce refueling work while service remains available. A qualified gas professional must check pressure, flow, meter and regulator capacity, and the pipe and hose sizes, including demand from other gas appliances. Do not assume an existing grill connection is large enough.
Westinghouse and DuroMax models to compare
The exact model matters more than the brand or the largest number on the box. These three tri-fuel machines are useful comparisons when considering a larger portable backup system.
Swipe the table sideways to see every column.
| Generator | Gasoline | Propane | Natural gas |
|---|---|---|---|
| Westinghouse WGen9500TFc | 9,500 W | 8,500 W | 7,500 W |
| Westinghouse WGen11500TFc | 11,500 W | 10,500 W | 9,500 W |
| DuroMax XP13000HXT | 10,500 W | 10,000 W | 9,000 W |
Manufacturer sources: [5][6][7] Older XP13000HXT revisions list different propane and natural-gas ratings. Check the manual and nameplate for the actual unit being purchased.
For a manual connection, compare continuous output on your chosen fuel, receptacle and breaker ratings, starting performance, neutral configuration, local service support and how you will move the machine. Check power quality against any sensitive equipment, HVAC controls or UPS units. Surge protection does not correct unsuitable generator power.
If you want automatic transfer, verify the exact generator and control compatibility before purchase. A 50-amp receptacle or remote-start button does not establish it. Westinghouse’s WATS200 compatibility listings do not establish compatibility with a DuroMax generator.
The Westinghouse WATS200
The WATS200 is a 120/240-volt, 200-amp service entrance rated automatic transfer switch for listed compatible Westinghouse generator arrangements. When correctly installed and prepared, it can start the generator after an outage, transfer power, restore utility power when available and shut the generator down. It provides battery charging and controls for up to four connected A/C loads. [8]
The 200-amp rating belongs to the transfer switch. It does not mean a portable generator supplies 200 amps. Available backup power still depends on the generator, inlet, cord, circuit and selected loads.
The generator must be safely positioned outdoors, fueled, maintained, connected and set as its instructions require. The A/C controls do not manage every appliance in the house. The WATS200 has an unswitched neutral, making the generator’s bonding and protection arrangement part of the compatibility review. Generator, inlet and power cord are separate items. [8][9]
Westinghouse’s smaller ST Switch is a different product: a 120-volt, 20-amp appliance device rated up to 2,400 watts. Check the model name when comparing estimates. [14]
For a home that needs automatic backup without moving a portable machine into place, compare the complete arrangement with permanently installed standby generator options.
Air conditioning, heat pumps and soft starts
A soft start can reduce the compressor’s brief starting-current demand on a compatible system. That may make an A/C unit more practical to run from a portable generator, provided there is enough capacity for its compressor, fans and other household loads once running. [11]
It does not increase the generator’s output. Other motors can start while the air conditioner is already running, so those demands belong in the calculation too.
Heat pumps need an additional check. Auxiliary or emergency heat, and sometimes defrost operation, can bring on electric resistance heat strips. A compressor soft start does not reduce that heating load. The system may need suitable controls or load management for generator operation.
Added soft starts are not compatible with every variable-speed unit or mini-split. Micro-Air’s EasyStart Home guide excludes inverter-driven compressors. Check the exact compressor and controls, along with the manufacturer’s requirements. [10]
Replacing your generator
An existing inlet may work with a replacement generator, but a matching plug is not enough. Check voltage, running output on the selected fuel, cord and receptacle ratings, neutral bonding and GFCI protection. Automatic transfer equipment also needs matching generator controls.
If the generator trips protection when connected, investigate the fault or compatibility issue. Do not defeat GFCI protection, remove ground pins or experiment with neutral and ground connections. Some transfer arrangements switch the neutral and others do not; the equipment instructions determine the correct setup. [9][12] Our electrical troubleshooting service can help identify the problem.
Before the next outage
Choose the operating location and cord route now. Decide who will start the generator and manage fuel, keep the equipment instructions accessible, and practice the approved procedure for your installation.
CPSC advises operating portable generators outdoors at least 20 feet from homes and buildings, with exhaust directed away from doors, windows and vents. Never run one in a garage, even with the door open. Use working CO alarms with battery backup, follow wet-weather instructions and let the engine cool before refueling. [13]
Keep up with the manufacturer’s oil, fuel, starting-battery and maintenance requirements. A portable generator does not provide uninterrupted power; equipment that cannot tolerate a power interruption needs its own backup plan. We also install home battery backup for suitable applications.
Questions before you schedule
Can every panel accept an interlock?
No. The exact catalog number, main disconnect, breaker layout and approved kit determine whether one can be fitted. A panel that cannot accept a suitable interlock may need a transfer switch or a panel change.
Can I use a 120-volt-only generator?
Some purpose-designed essential-circuit systems can use one. A typical 120/240-volt panel arrangement requires a compatible split-phase supply, and a 120-volt-only generator cannot run normal 240-volt appliances. An adapter alone does not resolve those differences.
Does changing fuel require a different inlet?
Usually the inlet does not change when you select another fuel supported by the generator. The supply must meet the manufacturer’s requirements, and your load plan must reflect output on that fuel. Gas piping is a separate part of the installation. See the fuel comparison for the differences.
Will a small propane cylinder work in an ice storm?
That depends on the generator, cylinder size, fill level, temperature and fuel-delivery equipment. For example, DuroMax specifies a minimum 40-pound propane cylinder for the XP13000HXT. Follow the exact model’s instructions and the fuel supplier’s guidance. [7]
Can I use my natural-gas grill connection?
Only after a qualified gas professional checks pressure, flow and the entire supply path. A fitting that connects does not establish enough fuel delivery, particularly with other gas appliances running. Gas availability during an outage is not guaranteed.
Does an ordinary interlock provide automatic starting?
No. An inlet and mechanical interlock require manual operation. Automatic starting and transfer need compatible controls and transfer equipment, with the generator prepared as its instructions require. The WATS200 section explains one available arrangement.
Do I need a permit in Greenville?
Greenville County requires a permit for electrical work. Your property’s jurisdiction determines the issuing office and inspection process. We identify those responsibilities in the written installation scope. [2]
What should I have ready for an estimate?
The generator model, your intended fuel and a list of equipment you need during an outage are a good start. If you have not bought a generator, we can review the panel and loads first. A photo of the closed panel is helpful; there is no need to remove its cover.
How soon can the installation be completed?
The scope, access, equipment availability, permits and inspection schedule determine timing. We confirm it when quoting the work. Arrange the connection before storm warnings, when you have time to choose equipment and learn the system.
What can increase the installation price?
A longer wire route, difficult access, panel repairs or changes, and different transfer equipment can add work. Ask whether the estimate includes the cord, generator, gas piping, soft start and wall repairs. SageCare provides the scope and price in writing, with a free estimate.
Does a CO shutoff sensor allow the generator closer to the house?
No. A CO shutoff is an additional safeguard. It does not replace outdoor placement, the recommended 20-foot separation from buildings, exhaust direction or working CO alarms. An open garage is not a safe operating location. [13]
Why might a generator’s GFCI trip at the house connection?
It could be a genuine fault or a mismatch involving neutral bonding, GFCI protection and the transfer equipment. The system needs a diagnosis against its equipment instructions. Bypassing protection is not the remedy. [12]
Get your generator connection ready
Tell us the generator model and what you want to keep running. We will check the panel, explain the options and give you a written installation price.
Equipment manuals and sources
Manufacturer information checked . Confirm the instructions and specifications for the exact equipment being installed.
- Schneider Electric: how a generator interlock works
- Greenville County: electrical permits and inspections
- Generac: generator output and receptacle limits
- Honda: approximate appliance running and starting wattage
- Westinghouse WGen9500TFc specifications
- Westinghouse WGen11500TFc specifications
- DuroMax XP13000HXT current specifications
- Westinghouse WATS200 automatic transfer switch
- Westinghouse WATS200 owner’s manual (PDF)
- Micro-Air EasyStart Home installation and compatibility guide (PDF)
- Micro-Air: what a compressor soft start does
- WINCO: generator GFCI and transfer-switch compatibility
- CPSC: portable generator placement, carbon monoxide and weather precautions
- Westinghouse ST Switch: the separate 120-volt appliance product
- Honda: power management and motor starting loads